Commercial Scale FPLC System

Bio-Pro commercial FPLC platforms from pilot to large-scale bioprocessing.

Commercial-scale Bio-Pro FPLC systems with quaternary diaphragm pumps, mass-flow metering, and process-ready UV/pH/conductivity options for protein and peptide purification.

Applications, Features & Benefits

  • Biologics manufacturing
  • Commercial protein purification
  • Process chromatography

Technical parameters

Showing 18 rows

Technical parameters
Bio-Pro30 Bio-Pro100 Bio-Pro150 Bio-Pro600 Bio-Pro1200 Bio-Pro2500 Bio-Pro4400
Pump Quaternary diaphragm pump — isocratic (S) single pump; gradient (G) dual pump Quaternary diaphragm pump — isocratic (S) single pump; gradient (G) dual pump Quaternary diaphragm pump — isocratic (S) single pump; gradient (G) dual pump Quaternary diaphragm pump — isocratic (S) single pump; gradient (G) dual pump Quaternary diaphragm pump — isocratic (S) single pump; gradient (G) dual pump Quaternary diaphragm pump — isocratic (S) single pump; gradient (G) dual pump Quaternary diaphragm pump — isocratic (S) single pump; gradient (G) dual pump
Flow range 0.5–48 L/h 3–100 L/h 6–180 L/h 10–600 L/h 20–1200 L/h 100–2500 L/h 300–4000 L/h
Flow accuracy Single pump: 1× E+H mass flow meter; dual pump: 2× E+H. Detection ±0.5%, system flow ±2% Single pump: 1× E+H mass flow meter; dual pump: 2× E+H. Detection ±0.5%, system flow ±2% Single pump: 1× E+H mass flow meter; dual pump: 2× E+H. Detection ±0.5%, system flow ±2% Single pump: 1× E+H mass flow meter; dual pump: 2× E+H. Detection ±0.5%, system flow ±2% Single pump: 1× E+H mass flow meter; dual pump: 2× E+H. Detection ±0.5%, system flow ±2% Single pump: 1× E+H mass flow meter; dual pump: 2× E+H. Detection ±0.5%, system flow ±2% Single pump: 1× E+H mass flow meter; dual pump: 2× E+H. Detection ±0.5%, system flow ±2%
Inlet / outlet valves Inlet: 2–8 (single) / 4–16 (dual); Outlet: 2–8 Inlet: 2–8 (single) / 4–16 (dual); Outlet: 2–8 Inlet: 2–8 (single) / 4–16 (dual); Outlet: 2–8 Inlet: 2–8 (single) / 4–16 (dual); Outlet: 2–8 Inlet: 2–8 (single) / 4–16 (dual); Outlet: 2–8 Inlet: 2–8 (single) / 4–16 (dual); Outlet: 2–8 Inlet: 2–8 (single) / 4–16 (dual); Outlet: 2–8
Pressure sensor 2× LABOM, 0–10 bar, ± ±0.1 bar 2× LABOM, 0–10 bar, accuracy ±0.1 bar 2× LABOM, 0–10 bar, accuracy ±0.1 bar 2× LABOM, 0–10 bar, accuracy ±0.1 bar 2× LABOM, 0–10 bar, accuracy ±0.1 bar 2× LABOM, 0–10 bar, accuracy ±0.1 bar 2× LABOM, 0–10 bar, accuracy ±0.1 bar
Bubble detector SONOTEC at inlet & precolumn, or AQ bubble sensor (adjustable) SONOTEC at inlet & precolumn, or AQ bubble sensor (adjustable) SONOTEC at inlet & precolumn, or AQ bubble sensor (adjustable) SONOTEC at inlet & precolumn, or AQ bubble sensor (adjustable) SONOTEC at inlet & precolumn, or AQ bubble sensor (adjustable) SONOTEC at inlet & precolumn, or AQ bubble sensor (adjustable) SONOTEC at inlet & precolumn, or AQ bubble sensor (adjustable)
UV OPTEK fixed (280/254 nm), 0–3 AU; or ECOM variable 4-λ (200–400 nm), 0–5 AU OPTEK fixed (280/254 nm), 0–3 AU; or ECOM variable 4-λ (200–400 nm), 0–5 AU OPTEK fixed (280/254 nm), 0–3 AU; or ECOM variable 4-λ (200–400 nm), 0–5 AU OPTEK fixed (280/254 nm), 0–3 AU; or ECOM variable 4-λ (200–400 nm), 0–5 AU OPTEK fixed (280/254 nm), 0–3 AU; or ECOM variable 4-λ (200–400 nm), 0–5 AU OPTEK fixed (280/254 nm), 0–3 AU; or ECOM variable 4-λ (200–400 nm), 0–5 AU OPTEK fixed (280/254 nm), 0–3 AU; or ECOM variable 4-λ (200–400 nm), 0–5 AU
pH HAMILTON, 0–14, ± ±0.1; online calibration with report HAMILTON, 0–14, accuracy ±0.1; online calibration with report HAMILTON, 0–14, accuracy ±0.1; online calibration with report HAMILTON, 0–14, accuracy ±0.1; online calibration with report HAMILTON, 0–14, accuracy ±0.1; online calibration with report HAMILTON, 0–14, accuracy ±0.1; online calibration with report HAMILTON, 0–14, accuracy ±0.1; online calibration with report
Conductivity HAMILTON 1 µS–300 mS/cm or OPTEK 1 µS–850 mS/cm HAMILTON 1 µS–300 mS/cm or OPTEK 1 µS–850 mS/cm HAMILTON 1 µS–300 mS/cm or OPTEK 1 µS–850 mS/cm HAMILTON 1 µS–300 mS/cm or OPTEK 1 µS–850 mS/cm HAMILTON 1 µS–300 mS/cm or OPTEK 1 µS–850 mS/cm HAMILTON 1 µS–300 mS/cm or OPTEK 1 µS–850 mS/cm HAMILTON 1 µS–300 mS/cm or OPTEK 1 µS–850 mS/cm
Tubing material ASME BPE (316L SS), Ra ≤ 0.4 µm ASME BPE (316L SS), Ra ≤ 0.4 µm ASME BPE (316L SS), Ra ≤ 0.4 µm ASME BPE (316L SS), Ra ≤ 0.4 µm ASME BPE (316L SS), Ra ≤ 0.4 µm ASME BPE (316L SS), Ra ≤ 0.4 µm ASME BPE (316L SS), Ra ≤ 0.4 µm
System pressure 6 bar 6 bar 6 bar 6 bar 6 bar 6 bar 6 bar
Bubble trap volume 50 ml 100 ml 500 ml 1000 ml 2500 ml 5000 ml 5000 ml
Tubing size 1/8" 1/4" 3/8" 1/2" 3/4" 1" 1.5"
Power supply 220 VAC 50 Hz 220 VAC 50 Hz 220 VAC 50 Hz 220 VAC 50 Hz 220 VAC 50 Hz 380 VAC 50 Hz 380 VAC 50 Hz
Power 1 kW 1 kW 1 kW 1 kW 1.5 kW 3 kW 5 kW
Dimensions (cm)① 103 H × 63 W × 98 D 118 H × 70 W × 105 D 118 H × 70 W × 105 D 123 H × 70 W × 113 D 123 H × 80 W × 120 D 180 H × 150 W × 180 D 180 H × 150 W × 180 D
Weight② 140 kg 150 kg 180 kg 200 kg 280 kg 580 kg 780 kg
Utilities Compressed air 5–7 bar, OD 10 mm air hose Compressed air 5–7 bar, OD 10 mm air hose Compressed air 5–7 bar, OD 10 mm air hose Compressed air 5–7 bar, OD 10 mm air hose Compressed air 5–7 bar, OD 10 mm air hose Compressed air 5–7 bar, OD 10 mm air hose Compressed air 5–7 bar, OD 10 mm air hose